Q.Sonic - Ultrasonic gas flow meter
The Elster-Instromet multi-path Q.Sonic ultrasonic gas flow meter is ideal for the calibration measurement of natural gas. The patented measuring path arrangement, in conjunction with advanced ultrasonic sensors and digital signal processing allows high accuracy with excellent long time stability.
The flow profile analysis of the meter allows renouncing the usual adoption of a flow conditioner.
| Technical data | Size overview | Downloads | |||
Q. Sonic - ultrasonic flow measurement with added value:
- Single and double reflection technology combined to 3-path, 4-path or 5-path meters
- Metrological identification of flow profile
- High stability by digital signal processing (CMB)
- Bi-directional use
- Excellent repeatability
- Excellent long-time stability
- No moving parts, wear-free measurement
- No pressure drop
- Under pressure exchangeable ultrasonic transducers
- Design in accordance with ISO standard CD17089
- Design in accordance with AGA-9 report
- Housing material steel A333/ A350, P355, special steel A316L, extra materials possible
- Pressure ratings: ASME 150 / 300 / 600 / 900, higher pressure ratings respectively DIN-flanges (PN) on request
- Approvals amongst others: PTB, NMI, GHOST, CMI
- ATEX Ex II 2 G
- Length of undisturbed upstream pipe:
without flow conditioner 10D
with flow conditioner 5D
Size overview
| Diameter | Qmin [m³/h] |
Qmax [m³/h] |
Vmax [m/s] |
G-Size | Max. path number |
Length Meter body |
| 4" 100 mm | 13 | 980 | 33 | G160 - G400 | 4 | 5D |
| 6" 150 mm | 32 | 2.220 | 33 | G250 - G1000 | 4 | 4D |
| 8" 200 mm | 32 | 3.840 | 33 | G400 - G1600 | 4 | 4D |
| 10" 250 mm | 50 | 6.050 | 33 | G650 - G2500 | 4 | 4D |
| 12" 300 mm | 78 | 7.810 | 30 | G1000 - G4000 | 5 | 3D |
| 16" 400 mm | 120 | 12.320 | 30 | G1600 - G6500 | 5 | 3D |
| 20" 500 mm | 190 | 19.370 | 30 | G2500 - G10000 | 5 | 3D |
| 24" 600 mm | 280 | 28.010 | 30 | G4000 - G16000 | 5 | 3D |
| 30" 750 mm | 400 | 46.000 | 30 | G6500 - G25000 | 5 | 3D |
The specified flow ranges apply to the respective nominal size for a wall thicknesses according Schedule 40. Depending on the metrological approval (eg PTB), the required pressure range and the resulting inside diameter of the meter the flow ranges may differ from the tabular value.
Larger diameters until 64" respectively 1600 mm are possible.