IRM-1

In addition to the range of turbine gas meters, Elster-Instromet started over two decades ago with the design of rotary gas meters. The biggest challenge was to design a reliable meter, unaffected by installation effects, and for this the unique cartridge was designed. The meter basically consists of a measurement module and a pressure housing, separating the flow measurement from the process. The result is a reliable, high performance meter, with unprecedented flexibility.


Technical data Downloads Special IRM-1G Special IRM-1S  
 

 Diameter  mm
 inch
 40 - 100
 1½ - 4
 Flow range size  metric
 imperial
 G 16 - G 250
 8C - 14M
 Qmax  m³/h
 cfh
 25 - 400
 883 - 14000
 Qmin  m³/h
 cfh
 0.40
 12
 Rangeability    1:20 - 1:250
 Maximum error of reading  Qt - Qmax
 Qmin - Qt*
 ±1 %
 ±2 %
 Repeatability  % of reading  < 0.1 %
 Body material    aluminium 
 ductile iron
 Screwed connection    no
 Flange ratings  PN
 ANSI
 16
 150
 Pressure range  MPa g
 bar g
 psi g
 0 - 1.6
 0 - 16 absolut
 0 - 232
 Temperature range
 (ambient, process)
   -20 to +60 °C
 Ingress protection    IP 65
 Index  gradual / continuous
 standard
 optional
 optional
 350 °
 universal index
 compact index
 multi index
 ENCODER S1D
 LF-sensor  standard  2
 HF-sensor  optional  2
 Lubrication    integrated sump

*   Qt = 0.2 Qmax for rangeability 1:20
     Qt = 0.1 Qmax for rangeability 1:50
     Qt = 0.05 Qmax for rangeability > 1:50

Subject to change without prior notice


High temperature resistant version

 

 Diameter  mm
 inch
 40 - 100
 1½ - 4
 Flow range size  metric
 imperial
 G 10 - G 250
 5C - 15M
 Qmax  m³/h
 cfh
 16 - 400
 565 - 14000
 Qmin  m³/h
 cfh
 0.35
 12
 Rangeability    1:20 - 1:250
 Maximum error of reading  Qt - Qmax
 Qmin - Qt
 ±0.5 %
 ±2 %
 Repeatability  % of reading  < 0.1 %
 Body material    ductile iron
 Screwed connection    no
 Flange ratings  PN
 ANSI
 16
 150
 Pressure range  MPa g
 bar g
 psi g
 0 - 0.4
 0 - 4
 0 - 60
 Temperature range
 (ambient, process)
 standard  -20 to +60 °C
 Ingress protection    IP 44
 Index  gradual / continuous
 standard
 350 °
 multi index
 LF-sensor  standard  4
 HF-sensor  optional  2
 HF-proximity sensor  optional  2
 Lubrication  standard  integrated sump


High pressure version

 

 Diameter  mm
 inch
 40 - 100
 1½ - 4
 Flow range size  metrisch
 imperial
 G 10 - G 250
 5C - 15M
 Qmax  m³/h
 cfh
 16 - 400
 565 - 14000
 Qmin  m³/h
 cfh
 0.35
 12
 Rangeability    1:20 - 1:250
 Maximum error of reading  Qt - Qmax
 Qmin - Qt
 ±0.5 %
 ±2 %
 Repeatability  % of reading  < 0.1 %
 Body material    carbon steel
 Screwed connection    no
 Flange ratings  PN
 ANSI
 25 - 100
 300 - 600
 Pressure range  MPa g
 bar g
 psi g
 0 - 10
 0 - 100
 0 - 1450
 Temperature range
 (ambient, process)
   -10 to +50 °C
 Ingress protection    IP 44
 Index  drehbar
 Standard
 Option
 Option
 350 °
 universal index
 compact index
 multi index
 LF-sensor  standard  4
 HF-sensor  optional  2
 HF-proximity sensor  optional  2
 Lubrication    oil pump